Language:CHINESESENGLISH

Home > News > Structural design knowledge: Prestressed steel anchor node which design requirements?
CONTACT US
  • Address:Pingtang Industrial District, Shipeng Village, Shishan Town, Nanhai District, Foshan City,
  • Phone:0757-81002668/0757-63323396
  • Fax:0757-81196682
  • Contact:Ben Zheng/13826981293 Kerry Lu/13751224830
  • E-mail:sbs@sbsprefabhouse.com
  • URL:

Structural design knowledge: Prestressed steel anchor node which design requirements?

Time:[2015-2-4]  Hits:4356

Structural design knowledge: Prestressed steel anchor node which design requirements?

     What prestressed steel anchor node design requirements?
     A structure based on the actual situation, should take pre-afterburner design value of 1.2 to 1.5 times the tendons (cable) design values of internal forces;
     Two pairs of important and complex node should Capacity Test conducted full-scale or scale model, the actual stress state of load cases node model tests should be consistent with the node;
     3 anchor node area should stress analysis and connected computing, and should take credible structural measures; node area should avoid overlapping weld, cut, etc; structural, mechanical complex node can be cast steel nodes.

Copyright:佛山市beat365官方网站钢结构有限公司 Foshan Shengbang Steel Structure Co., Ltd. Record Number:粤ICP备13078463号